The information in this instruction manual is directed at the following groups of people:
Heating and sanitary professionals and trained personnel
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns of possible life-threatening injury.
This symbol warns of possible serious injury.
This symbol warns of possible injury.
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g. EN) and/or in Germany (e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The Prevista Pure standing bracket is used for the free-standing mounting of Prevista Pure blocks.
Break the locking clips off the wall mountings.
Remove the protection box.
Push the wall mountings into the element.
Insert the locking clips.
Adjust the construction height of the WC block in accordance with the on-site marking of the upper edge of the finished floor.
Mark the fixing points on the wall.
Drill the holes.
Attach the standing bracket to the WC block.
Mark the holes on the floor.
Drill the holes.
Insert the dowels.
Tighten the WC block and the standing bracket via the mounting brackets using a fork spanner.
Insert the protection box.
Shorten the standing bracket.
Attach the standing bracket to the WC block.
Adjust the construction height of the WC block in accordance with the on-site marking of the upper edge of the finished floor.
x = 1000 mm
Drill the holes.
Insert the dowels.
Tighten the WC block and the standing bracket via the mounting brackets using a fork spanner.
Insert the protection box.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.